Drive Tek Vector AC Motor 3kW 3000rpm B5 Flange Mtd 1024ppr
Inverter rated, vector or variable speed motors are used when speed stability and speed range of up to 100:1 are required (dependant on AC inverter drive performance) a Force Vent and Encoder are fitted. We can supply Inverter rated motors for use with an AC Inverter from 0.18kW to 18.5kW available in 2 and 4 pole (max 18.5kW - 2Pole) (max 15kW – 4Pole) B5 Flange, B14 Face or B3 Foot Mounted.
The Force Vent Inverter Rated Vector Motor comprises of 3 individual units.
AC Motor
Force Vent Unit
Encoder
For Specifications see individual units below
Inverter rated variable speed AC Motor comprises of :-
This new range of Drive-Tek, IE2 high efficiency AC Motors has been specially developed to meet the new European Efficiency Directive that came into law in the UK in June 2011. It is produced using high quality components to make an AC Motor that has one of the best specifications available today with a value for money price.
AC Motor Part Number I2----3-2B5
Power 3kW AC Motor
Frame D100L
Rated Speed 3000rpm
B5 Flange Mounted
1024 ppr Pulse per revolution
The result is a high quality multi-mount range of AC motors with certified lE2 efficiency and has standard features that are options on some of the main competitor products:
Drive-Tek Force Vent Units are manufactured to the highest standard using high quality components with high volume flow using flow-optimised design and rust resistant materials
With inside Diameter of 196mm Frame Size D100L
*** When fitting to none Drive-Tek or Teco Inverter Rated Motor then consideration to the internal depth must be taken into account. To stop the rear end of the motor fouling with the internal fan. Please see dimention AF1 The force vent is supplied with optional extension tube to increase depth by 60mm Approx to allow for Encoder provision see AF2
Part Number: IEC100 / I/Dia196mm
Drive-Tek Force Vent Unit Features:
Fit Drive-Tek or Teco LVED Inverter rated AC Motors or motors with 196mm diameter fixing holes
Frame Size D100L
Optional extension tube supplied ***
Can be used with 230V 1PH AC or 400V 3PH AC
Optional extension tube to fit over Encoder if required
Inside Diameter of 196mm
High volume flow through flow-optimised design
Modular system for various applications
Sufficient clearance to allow fitting of an Encoder if required
EMC-compliant
Very good vibration resistance due to robust sheet-metal/die cast housing
Galvanized sheet metal, seawater-resistant die cast alloy
cURus certified
Consistent IP66 protection for all versions
Finished RAL7032 Gloss to match TECO LVED and Drive-Tek motors
Drive-Tek Force Vent Units are supplied as standard with a capacitor so they can be wired as 230V 1PH AC or 400V 3PH AC which is very useful if being stocked as a spare part as one unit covers both 1/3PH motor supply
Drive-Tek Force Ventilation Units are designed to fit the the Drive-Tek range of AC motors in frame sizes from D63 to D160 (0.18kW to 18.5kW) (max 15kw 4pole) they can be supplied fitted to the motor of your choice or retro fitted by yourself. The Force Vent Unit has the option of an extension tube to extend the length if an encoder is fitted. Please be aware that different manufactures have different dimensions for the fitting of fan cowls and these are designed to fit the Drive-Tek range of motors we can supply Force Vent units to fit other brands on request.
Standard AC motors are designed for fixed speed operation and when used in conjunction with an AC Drive (inverter) they are subject to conditions which invariably reduce motor performance and life. Typically standard AC motors can operate over a 4: 1 speed range (50 to 12.5Hz) beyond this it is necessary to allow for lack of cooling due to the motor fan running slower and excess heat being created within the motor with the result of burning out the motor.
The easiest way to overcome this problem is to fit a Drive-Tek Forced Vent unit which is an independently powered fan unit that replaces the standard motor fan. The Drive-Tek Force Vent Unit overblows a constant stream of air over the motor and ensures optimal cooling regardless of operating speed.
Typically using a Drive-Tek Force Ventilation Unit with a standard AC Motor and a mid-range AC Drive (Inverter) then a 20:1 (50 to 2.5Hz) speed range should be possible without heat damaging the motor and with a high performance AC Drive (Inverter) and closed loop feedback (Encoder) then 100:1 speed range would be possible. Often referred to as a Inverter rated AC Motor or Variable Speed AC Motor(Always check the AC Inverter Drive performance figures)
Drive-Tek Incremental Encoder Features
PPR (Pulses per Revolution) 1024 ppr
Bore Type: 14mm Through Bore
Protection: IP65
Operating Temperature: -20°C to +100°C
Maximum Speed: 7500rpm continuous
Torque: 0.0008Nm
Shaft Loading: Flexible Mounted (supplied)
Cable: 5 metres Screened, oil and salt water
Impulse Frequency: 800KHz (Max)
Current Consumption: 40mA without load
Model Drive-Tek 60HA
Hollow Shaft 14mm Diameter Bore
Standard pulses are 1024PPR or 2048PPR (other pulses available on request)
Supply Voltage 5-32VDC
The Drive-Tek 60HA encoder is designed to fit directly on to the motor shaft or any shaft where position, direction, or velocity information is needed. The advanced electronics provides superior performance and high noise immunity. The Drive-Tek encoder features a simple clamp mount for easy mounting on a 14mm diameter shaft, other hollow bore sizes available on request, whilst a universal anti-rotation flex mount maintains housing stability. Alternatively, if body rotation is required, there is the option of rotatable mounting on a fixed radius instead.